beautypg.com

Xample, 2 - pc b, Ased dial – CTI Products MCN RCD System Planner User Manual

Page 39: Ystem for, Pectra, Ricsson, Omparator, Eceivers, Igure, 15 d

background image

Appendix C System Examples

MCN Comparator Display System Planner

Page 35

7.2

Example 2 - PC Based dial-up System for Spectra-TAC or
Ericsson Comparator-- 12 Receivers

Figure 15 shows a simple dial-up system to monitor and control 12 or 16 receivers. This system
assumes the following:

Spectra-TAC or Ericsson / GE Comparator, 16 (or 12) Receivers maximum,

Dial-Up PC Display

CIBs & HIB will be rack mounted

Wiring will be directly to the back of the comparator backplanes with no punch blocks.

COM 2

COM 1

CA-80196-100

2

COMPARATORS

HIB

CIB

CIB

T

MODEM

MODEM

T

1

P/S

IN

OUT

IN

IN

OUT

REMOTE PC

Figure 15 Dial-Up Display for up to 16 Receivers

Equipment List for Example System 2

Item

Part Nmber

Description

Qty

1

S2-60442

Comparator Interface Module (CIB)

2

2

S1-60424

Host Computer Interface Module (HIB) and
MCN Remote Comparator Display DOS Software

1

3

89-10843

Male to Blunt Cable 25’

2

4

S2-60445

HIB - Modem 3’ Serial Cable

1

5

S2-60450

PC (9 or 25 pin) to Modem Cable

1

6

99-10962

Modem V.34 28.8 Kb Dial-up

2

7

S2-60435

Quad Rack Mount Size A (1 Rack Unit high)

1

8

S2-60438

9” Network Cable

2

9

S2-60318

Terminator (1 each)

2

10

81-10398

Power Supply N. American

1

Order the PC separately. See the System Hardware Requirements section for details.