Appendix c system examples, Xample, 1 - pc b – CTI Products MCN RCD System Planner User Manual
Page 38: Ased, Ystem for, Digitac c, Omparator, Eceivers, Igure, 14 - 8 d

Appendix C System Examples
Page 34
MCN Comparator Display System Planner
7.
Appendix C System Examples
The following examples show how MCN modules are combined to form various systems, as well as the
capabilities of those systems.
7.1
Example 1 - PC Based System for DIGITAC Comparator-- 8
Receivers
Figure 14 shows a system that provides local monitoring and control of up to 8 receivers utilizing a PC
as the operator interface. This system assumes the following:
•
DIGITAC Comparator, 8 Receivers
•
PC Display
•
CIB will be mounted on the rear of the Digitac Comparator
•
North American power supply is required.
•
100 feet between PC and comparator
•
HIB will be rack-mounted in the operator console.
COM 2
COM 1
CA-80019-100
CIB
1
COMPARATOR
HIB
T
P/S
IN
OUT
IN
OUT
T
LOCAL PC
Figure 14 - 8 Digitac Receivers with PC Display
(P/S = Power Supply, T = Network Terminator)
This is an easy system to order since there is a packaged model for an 8-receiver DIGITAC comparator
with PC display: Order the following items:
Equipment List for Example System 1
Item
Part Nmber
Description
Qty
1
S2-60442
Comparator Interface Module (CIB)
1
2
S1-60424
Host Computer Interface Module (HIB) and
MCN Remote Comparator Display DOS Software
1
3
S2-60441
HIB - PC (9 or 25 Pin) 6’Serial Cable
1
4
S2-60437
DIGITAC Bracket and Ribbon Cable (for CIB)
1
5
S2-60435
Quad Rack Mount Size A (1 Rack Unit high) (for HIB)
1
6
89-10836
100 Ft Network Cable
1
7
S2-60318
Terminator (1 each)
2
8
81-10398
Power Supply N. American
1
Order the PC separately. See the System Hardware Requirements section for details.