CONTREX ML-TRIM User Manual
Page 88
3 - 54
Character 5, 6 - Parameter Number:
These characters identify the Control Parameter that you want to change
(i.e., “16” = CP-16).
Characters 7 through 10 - DATA:
These characters transmit the new value for a Control Parameter that you want to
change. The Data must be within the range specified in Appendix D.
Character 11 - Data Format:
Character 11 indicates the decimal location and polarity of the data that was
transmitted in characters 7 through 10. Use the following codes to indicate decimal
location and polarity:
Code
Format
0
+XXXX
1
+XXX.X
2
+XX.XX
3
+X.XXX
4
-XXXX
5
-XXX.X
6
-
XX.XX
7
-X.XXX
8
+XX.XX
.
Codes “0 ” through “7” are valid for CP-20 and CP-21. All other Code Parameters
have either fixed or derived decimal locations and must use Code “0”. Code “8”
does not apply to the parameter send.