beautypg.com

Output monitoring, Output monitoring -42 – CONTREX ML-TRIM User Manual

Page 76

background image

3 - 42

Output Monitoring

These MPs monitor the ML–Trim's outputs.

MP-47 SPEED COMMAND OUT

The Speed Command Out (MP-47) displays the level of calibrated full scale analog
output to the motor drive (J2 pin 1). The Speed Command Out (MP 47) is displayed as
a percentage; 100 represents 100% of the calibrated full scale analog output.

MP-56 LOGIC OUTPUTS

The Logic Outputs (MP-56) displays the status of the Drive Enable and the Alarm digital
outputs. The number “1” indicates an inactive or de-energized (logic high) level. The
number “0” indicates an active or energized (logic low) level. In the example below,
“Alarm” is the inactive or de-energized (logic high) level.

Drive Enable (J5 Pin 16)

Alarm (J5 Pin 17)

Not Used

Not Used

Code