Power Restore

ToggleLinc Dimmer stores all of its scenes, properties, etc. in its internal non-volatile memory so all
settings are retained after a power outage. Upon power being restored, ToggleLinc will return its
connected load(s) and all LEDs to their states prior to power outage.

Programming ToggleLinc Dimmer as Part of an X10 Network

Like most INSTEON devices, ToggleLinc Dimmer is X10-ready, meaning it can both send and respond to
X10 commands. However, ToggleLinc Dimmer does not ship with an X10 address, so you must set one
up when first installing ToggleLinc Dimmer or after performing a factory reset.

Adding an X10 Address

1) Press and hold ToggleLinc’s Set button until it beeps (about 3 seconds).

ToggleLinc’s status LED will blink.
You will have 4 minutes to complete the next step before linking mode times out.

2) Using an X10 controller, send the X10 address you want to assign to ToggleLinc Dimmer followed by

the ON command three times.

For example, to assign the address A1, you would send A1-ON-A1-ON-A1-ON.

3) Once ToggleLinc Dimmer has received the sequence, it will exit linking mode.

ToggleLinc will double-beep.

Removing an X10 Address

If you are no longer going to utilize an X10 address associated with ToggleLinc Dimmer, it is very
important that you remove its X10 address. Otherwise, ToggleLinc will still listen for X10 commands
(somewhat hindering INSTEON reception) and may respond to spurious X10 “noise.” Furthermore,
ToggleLinc will transmit an X10 address and command every time the button is tapped.

1) Press and hold ToggleLinc’s Set button until it beeps (about 3 seconds).

ToggleLinc’s status LED will blink.

2) Press and hold ToggleLinc’s Set button until it beeps again.

ToggleLinc’s status LED will continue blinking.
You will have 4 minutes to complete the next step before unlinking mode times out.

3) Using an X10 controller, send the X10 address you want to remove followed by the ON command

three times.

For example, to remove the address A1, you would send A1-ON-A1-ON-A1-ON.

4) Once ToggleLinc Dimmer has received the sequence, it will exit unlinking mode.

ToggleLinc will beep.

Advanced X10 Programming

Instructions on setting X10 primary address and scene addresses can be found online:

http://www.smarthome.com/insteon-x10-programming.html

Advanced Features

Add Multiple Scene Responders

1) Press and hold ToggleLinc’s Set button until it beeps.

ToggleLinc status LED will start blinking.