INSTEON SwitchLinc 2-Wire Dimmer (RF) (2474DWH) Quick Start User Manual
Quick start guide, Switchlinc™ 2-wire dimmer (rf) insteon, Remote control dimmer - model: 2474dwh
2474D Rev. 7/16/2012 12:38 PM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (s
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
Quick Start Guide
SwitchLinc™ 2-Wire Dimmer (RF)
INSTEON
®
Remote Control Dimmer - Model: 2474DWH
What’s in the Box?
•
SwitchLinc 2-Wire Dimmer
•
Three (3) wire nuts
•
Two (2) screws
Tools Needed
•
Slotted screwdriver
•
Phillips screwdriver
•
Wire cutter/stripper
•
Voltage meter
Installing SwitchLinc
1) At electrical panel, turn off circuit breaker(s) feeding wall box (verify that
power is off)
2) Remove wallplate, unscrew existing switch and gently pull out
3) Disconnect wires from switch
4) After making sure the wires are not touching, turn breaker back on
5) Use a voltage meter to identify the line, load and ground wires
6) Turn breaker back off
7) Connect wires as follows with wire nuts:
8) Mount SwitchLinc back into wall box, orienting the LED bar on left
9) Turn breaker back on
SwitchLinc LED bar and connected light/load will turn on
10) Test by tapping SwitchLinc on and off
Connected light/load will turn on and off
11) Reinstall the wallplate
Making SwitchLinc an INSTEON Responder
1) Press and hold controller button until it beeps
Controller LED will start blinking
2) Tap SwitchLinc on
Connected light/load will turn on
3) Press and hold SwitchLinc’s Set button until it double-beeps
Controller LED will stop blinking and unit will double-beep
4) Confirm link by tapping controller’s button on and off
Connected light/load will turn on and off
Owner’s Manual and Tech Support
Owner’s Manual and current Quick Start Guide
Call: INSTEON Support Line at 800-762-7845
CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting
fixture or a transformer-supplied appliance.
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer
pour commader une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.
1
If the wires cannot be detached by unscrewing them, cut the wires where they enter the switch, then strip ½” of insulation off the ends
SwitchLinc Wires
Wall Box Wires
Bare copper
Ground (bare copper, green wire or green screw)
Red
Load (light)
Black
Line (commonly black)
OFF/
Dim
Setup
LED
ON/
Brighten
Set