DX121 EQUIPMENT SPECIFICATIONS

BS121 Base Station

GENERAL

Frequency Range:

All, 2400 to 2483.5 MHz

Low, 2401.92 to 2439.94 MHz

High, 2443.39 to 2481.41 MHz

Frequency Response:

200 Hz to 3.5 kHz

Power Requirements:

100-240VAC, 50-60Hz or 12-14VDC

Temperature Range:

32-122°F (0-50°C)

Size:

1.62” x 5.50” x 7.88” (4.1 x 14 x 20 cm)

Weight:

1.2 lbs. (.59 kg) with battery

# of Beltpacs per Base:

4 can be registered

Only 1 can have full-duplex communication at a time

4-Wire I/O:

60

0Ω balanced, level adjustable, simultaneous operation with headset

Headset I/O:

20

0Ω, level adjustable

Front Panel Controls:

Power button, REGister Beltpac and CLR/BND buttons,
RESET switch, HEADSET IN and OUT level adjustments,
4-Wire IN and OUT level adjustments

Front Panel Indicators:

POWER LED, STATUS display, IC and ISO Receive LEDs,

Battery Power LED, Battery Charger RDY and CHG LEDs

Rear Panel Controls:

Primary/Secondary switch

Antenna Type:

External ½ -wave dipole (R-TNC connector)

RX/TX horizontal/vertical diversity

System Distortion:

<2%

Communication Security:

64-bit encryption dual-slot diversity

TRANSMITTER

Type:

Frequency hopping, spread spectrum

Transmit Power:

100mW burst

Modulation Type:

Gaussian filtered FSK, TDM

Frequency Stability:

13 ppm

Harmonics/Spurious:

Exceeds FCC and ETSI specifications over temperature

RECEIVER

Type:

Frequency hopping, spread spectrum

RF Sensitivity:

<

−90dBm w 10

-3

BER

Frequency Stability:

13 ppm

Distortion:

<2%

BATTERY CHARGER

Battery charging time:

<3 hours