Key to Figure 20: Wiring an IMF-102 rear panel to a TEL-14 interface module
Connector
Instruction / description
A
DB-9M connector. Connects to the first telephone line, line A.
B
RJ-45 connector. Connects telephone line A to the matrix frame.
C
DB-9M connector. Connects to the second telephone line, line B.
D
RJ-45 connector. Connects telephone line B to the matrix frame.
Table 17: Key to Figure 20: Wiring an IMF-102 rear panel to a TEL-14 interface module
Note:
To allow use of a common RJ-11 terminated telephone line, Clear-Com provides two DB-9F
to RJ-11 adapters (Clear-Com part 770025).
For internal dip-switch settings and adjustments, see the TEL-14 manual.
Connecting a TEL-14 interface to the telephone line
Connecting the telephone line can be accomplished with one of two methods:
• Use the RJ-11 to DB-9F adapters supplied by Clear-Com with the TEL-14 interface
module.
• Directly wire each telephone line to a DB-9F connector using the pinouts as shown in
the following figure (which displays the wiring diagram of the RJ-11 to DB-9F
adapter).