Fluid Components International MT91 Manual Operation User Manual
Page 3
CHAPTER 3 - OPERATION
FLUID COMPONENTS INTL
Doc. No. 003185 Rev. B
3 - 3
Model MT91 Multipoint Flowmeter
•
The first menu option places the units display into the normal display mode. When the system is in this mode,
flow and/or temperature measurements are displayed. While in the normal display mode, pressing any key will
cause the main menu to display.
•
The Setup group presents the options for customizing the system inputs and outputs. Most of the settings will
be made through menus in this group.
•
The diagnostics group provides displays that help isolate problems and test the system integrity.
•
The calibration group is used primarily by factory technicians, but there are displays that can be helpful to the
customer.
•
The verify group provides a means to view the values of important system parameters.
•
Finally, the firmware version is available for display.
0.0 MAIN MENU
1=Normal Display
2=Setup
3=Diagnostics
4=Calibration
5=Verify
6=Version
7=Time Delay
2.0 SETUP
1=Display
2=Outputs
3=Communications
4=Configuration
5=Password
6=Clock
3.0 DIAGNOSTICS
1=System Status
2=Output Tests
3=Calibration Tests
4=Schedule Tests
4.0 CALIBRATION
1=Cal Initialize
2=Cal Inputs
3=Cal Outputs
4=Cal Flow
5.0 VERIFY
1=Verify Setup
2=Verify Cal
Version x.xx
Release Date
dd-mm-yy
CH1: 47.8 SF/S
CH2: 89.2 F
K1 K2
System OK
2.1 DISPLAY
1=Flow
2=Temperature
3=Screen Setup
2.3 COMMUNICATIONS
1=Mode
2=Baud
3=Protocal
4=RS-485 Address
2.4 CONFIGURATION
1=Setup User Config
2=Setup Factory Cfg
3=Save Config
2.5 PASSWORD
1=Change User PW
2=Enable PW
3.1 SYSTEM STATUS
1=Sensors
2=Heaters
3.2 OUTPUT TESTS
1=Analog Output Test
2=Relay Test
3.3 CALIBRATION
TESTS
1=Start Test
2=Display Results
3.4 SCHEDULE TESTS
1=Calibration Drift
2=Enable Auto Test
2.2 OUTPUTS
1=Assign Heads
2=Analog
3=Relays
4=Filter
5=Corrections
4.1 CAL INITIALIZE
1=All Cal Parms
2=Input Cal Parms
3=Output Cal Parms
4=Flow Cal Parms
5=Misc Cal Parms
4.2 CAL INPUTS
1=Sensor Type
2=Excitation
3=Heaters
4=Normalize to R
5=Unipolar rR & dR
6=Bipolar rR & dR
7=Display dV &dV
4.3 CAL OUTPUTS
1=Analog Outputs
4.4 CAL FLOW
1=Coefficients
2=Limits
3=Temp Comp
4=Offset
5.1 VERIFY SETUP
1=Flow
2=Temp
3=Outputs
4=Communication
5.2 VERIFY CAL
1=Inputs
2=Outputs
3=Flow
Normal Display
C00221-1.vsd
7.0 TIME DELAY
Enter Minutes:
(1)
?
7.0 TIME DELAY
Output Frozen
Press any key to stop
Time Left: 0:07
2.6 SET CLOCK
1=Set Clock
2=Auto Offset
Figure 3-3 Menu Flowchart