Fluid Components International CMF Series Guide User Manual
Page 4
FLUID COMPONENTS, INTL
FlexCOR
TM
Model CMF Series Coriolis Flow Meter 4 Doc. No. 06EN003318 Rev. B
Locate the instrument as far away as possible from components that generate
mechanical vibration in the piping.
Vibration
Cross-Talk
If the instruments are located close to each other, e.g. in the same pipe section,
the instruments may interfere with each other's measurements, especially with
low flow applications. Install a flexible connection between instruments,
instead of a hard pipe connection.
Avoid mounting the instrument on the same steel frame. I.e. insulate the meters
mechanically.
CMF- B Through F SENSOR INSTALLATION
Horizontal Mounting in Pipe
Horizontal mounting
for Gas applications
Not for Liquid applications
Horizontal mounting
for Liquid applications
Direction of Flow
Static back pressure min. 0.1 bar
Valve
Reverse
Forward
Valve
Ok for gas
or liquid
applications
Ok for gas
applications
Only
Vertical Mounting in Pipe
Direction of
Vertical Flow
Direction of flow
Valve
Static back
pressure min.
0.1-0.2 bar
Locate the flowmeter as far away as possible from
components that generate mechanical vibration in the
piping.
Vibration
Ensure that there is no direct connection with them e.g.
by using flexible connections. The flowmeter can be
located after a bend.
Mounting the CMF-B through F sensors are very similar to mounting the CMF-A. A pictorial account of mounting will be given.