17
Installationandwiring
Type 8025 /8035 Batch
7.3
installation of a panel version
install the panel version of the device in a cabinet with
a protection class at least ip54 to ensure a degree of
pollution 2 inside the cabinet.
▶
→
To▶cut▶the▶opening▶in▶the▶cabinet▶door,▶use▶the▶supplied▶drilling▶
jig,▶respecting▶the▶dimensions▶indicated▶in▶„Fig.▶10“.
95
80
76
50
95 80 76 50
Fig. 10: Dimensions of the drilling jig [mm]
▶
→
Insert▶the▶4▶screws▶in▶the▶housing▶(from▶the▶front).
▶
→
Insert▶the▶seal▶on▶the▶external▶threads▶of▶the▶4▶screws▶(rear▶of▶
the▶housing).
▶
→
Put▶the▶assembly▶on▶the▶cutout,▶electronics▶turned▶to▶the▶inside▶
of▶the▶cabinet.
▶
→
Put▶the▶4▶washers▶on▶the▶4▶screws.
▶
→
Put▶a▶nut▶on▶each▶of▶the▶4▶screws▶and▶tighten▶the▶nuts▶to▶secure▶
the▶device▶to▶the▶cabinet.
Seal
Nut
Washer
Screws
Cable▶clip
Fig. 11: Installation of a 8025, panel version