Burkert Type 8035 User Manual
Page 18
16
Installationandwiring
Type 8025 /8035 Batch
▶
→
Respect▶the▶following▶additional▶mounting▶conditions▶to▶ensure▶
that▶the▶measuring▶device▶operates▶correctly:▶
▶
- Ensure▶that▶the▶pipe▶is▶always▶filled▶in▶the▶section▶around▶the▶
device▶(see▶„Fig.▶8“).
▶
- When▶mounting▶vertically▶ensure▶that▶the▶flow▶direction▶is▶in▶an▶
upward▶direction▶(see▶„Fig.▶8“).
Horizontal▶mounting
Correct
Incorrect
Vertical▶mounting
Correct
Incorrect
flow▶direction
Fig. 8: Filling of the pipe
▶
→
If▶necessary,▶use▶a▶flow▶conditioner▶to▶improve▶measurement▶
precision.
7.2.2 installation onto the pipe
1
2
3
5
4
6
▶
→
Install▶the▶S020▶fitting▶into▶the▶pipe▶taking▶
into▶account▶the▶recommendations▶in▶chap.▶
„7.2.1“
.
▶
→
Check▶that▶there▶is▶a▶seal▶on▶the▶fitting▶and▶
that▶ it▶ is▶ not▶ damaged.▶ Replace▶ the▶ seal▶ if▶
necessary.
▶
→
Check▶ that▶ there▶ is▶ a▶ seal▶ (mark▶ 6)▶ on▶ the▶
flow▶sensor.
▶
→
Insert▶the▶nut▶(mark▶3)▶on▶the▶fitting.
▶
→
Insert▶the▶snap▶ring▶(mark▶2)▶into▶the▶groove▶
(mark▶5).
▶
→
Position▶the▶device▶in▶order▶the▶arrow▶on▶the▶
side▶of▶the▶housing▶indicates▶the▶direction▶of▶
the▶flow.▶The▶totalizers▶will▶increment.
▶
→
Insert▶the▶device▶(mark▶1)▶into▶the▶fitting.
▶
→
Tighten▶the▶nut▶(mark▶3)▶by▶hand▶on▶the▶
device.
Fig. 9: Installation of a 8025 Batch, compact version, into an
S020 fitting
English