English changing the printed circuit board, Replacing the valve group – Burkert Type 1066 User Manual
Page 35
1066 - 33
R
EPAIRS
english
Changing the printed circuit board
Proceed as follows:
Remove the cover.
Before disconnecting, mark the electrical connections so that it will
bepossible to reconnect them without error.
Disconnect all electrical connections from the printed circuit board
(plug and / or screw connections).
Loosen the four screws (Torx 10) with which the cover plate is secured.
Remove the cover plate.
Remove all circuit boards (no screw fittings).
Insert the new circuit boards.
Replace the cover plate.
Screw down the cover plate (Torx 10; tightening torque 0.7 Nm).
Reconnect the electrical connections according to the markings made
earlier.
Refit the cover.
ATTENTION!
Ensure the correct fit of the circuit board an the screw
heads in the projections and/or the cut-outs in the
cover plate!
Plate for
24 V DC
without communication
Replacement
ASI module, moulded
Replacement
DeviceNet, moulded
Replacing the valve group
The valve group consists of a connection plate with 1, 2 or 3 flanged
valves of the type 6510 and the O-rings for the fluidic flange to the
housing.
NOTE
Proceed as follows:
Remove the cover.
Before disconnecting from the circuit board, mark the electrical
connections so that it will be possible to reconnect them without
error.
Disconnect all electrical connections from the printed circuit
board (screw connections).
Loosen the 2 screws (Torx 20) with which the valve group is
secured.
Remove the valve group complete with its O-rings.
Fit the new valve group complete with its O-rings.
Screw down the valve group (Torx 20; tightening torque 1.5 Nm).
Reconnect the electrical connections according to the markings made earlier.
Refit the cover, ensuring that the O-rings are correctly seated.
ATTENTION!
Ensure the correct fit of the printed circuit boards into
the housing projections!
For 24 V DC without communication, ASI and
DeviceNet, only a change of the whole valve group
is permitted.
Valve group, optionally
with 1, 2 or 3 valves
- 24 V DC without
communication
- ASI (24 V DC)
- DeviceNet (9 V DC)