beautypg.com

English pneumatic data, Electrical data – Burkert Type 1066 User Manual

Page 12

background image

10 - 1066

T

ECHNICAL

D

ATA

english

Pneumatic data

Port connections

Compressed air/Exhaust air

G 1/4

Service ports tube hose connection
6/4 mm or 1/4 inch, plug-in

Pressure range

2.5 to 7 bar

Air flow, control valve

110 l/min Type 6510, 40 l/min Type 6106

Flow: Q

Nn

- value air (l/min)

Measurement at +20 °C, 6 bar pressure at the valve inlet and 1 bar
pressure difference

Response times

Type 6510 / Type 6106
Opening 15 / 23 ms

Closing 10 / 21 ms

Measurement at valve outlet at 6 bar and +20 °C
Opening:

pressure rise 0 to 90 %

Closing:

pressure fall 100 to 10 %

Control range

min. stroke 2mm

max. stroke 73 mm

Electrical data

Protection class

IP 67

Operating voltage

without communication

24 V DC ±10 %

24/110/230 V UC ±10 %

with communication

in accordance with the ASI and DeviceNet specification

Max. electrical power loss

5 W for 3 x Type 6510 or 1 x Type 6106

Connections

Control heads
without communication:

Multipol (8-pole round plug DIN 45326) for 24 V DC

(8-pole screw terminals) for 24 V DC
2 x 6-pole screw terminals for 24/110/230 V UC

Control heads
with communication:

ASI:

Cut-clamp connector and cable fitting
M12 plug and cable fitting
M12 flange plug, 4-pole

DeviceNet:

5-pole M12 plug connection

Solenoid valves

Nominal power

1 W Type 6510 / 3 W Type 6106

Operating mode

continuous (ED 100 %)

Proximity switches

Operating voltage

8 to 30 V DC

Output signal

max. 100 mA, short-circuit proof

Micro-switch

potential-free, max. 1 A switched current