beautypg.com

Technical data, Operating conditions 6.1, Application conditions 6.2 – Burkert Type 6212 User Manual

Page 4: Conformity 6.3, Rating plate 6.4

background image

12

6. Technical daTa

Operating conditions

6.1.

The following values* are indicated on the rating
plate:

Voltage

(tolerance ±10 %) / current type

Coil power consumption

(active power in W - at operating temperature)
Pressure range

Housing material

brass (MS) or stainless steel (VA)
Seal material

FKM, EPDM, NBR

* see description of rating plate below

Operating principle 2/2-way valve:

A (NC)

A

P

B (NO)

Protection class:

IP65 in accordance with DIN EN 60529
/ IEC 60529 with device socket

english

13

application conditions

6.2.

Allowable temperatures
Ambient temperature:

max. +55 °C

Heat-radiating energy sources must not additionally heat
the unit.

Permitted medium temperature depending on seal
material:

FKM

0 ... +50 °C

NBR

0 ... +50 °C

EPDM

-10 ... +50 °C

Permitted medium depending on seal material:

Seal material

Permitted medium

FKM

Per-Solutions, oil, fat, diluted acids

NBR

Neutral medium, such as compressed
air, water, hydraulic oil

EPDM

Oil and fat free medium, diluted base

Duty cycle:

100% continuous rating (operating with
24 V/DC),
40 %, 20 min. intermittent duty (operating
with 110-120 V/UC, 230-240 V/UC)

english

14

Important information concerning functional reliability
during continuous operation!
If switched off for a long period, at least 1-2 activations
per day are recommended.

Service life
High switching frequency and high pressures reduce the
service life.

conformity

6.3.

CE mark conforms to EMC Directive 2004/108/EEC only if
cables, plugs and sockets connected correctly.

rating plate

6.4.

Rating plate

Location of the rating plate

Fig. 1:

english

15

6.4.1. description of the rating plate

6212 A 13,0 FKM MS

M

a

d

e

in

G

e

rm

a

ny

00138961

W11 ML

230-240V AC/DC 4W

G1/2 P

N0,2

-

10bar

Type

Operating

prinziple

Orifice

Seal material

Housing material

Id.-Number

Manufacturer code

Voltage, Power consumption

Connection thread, Nominal

pressure

Example:

Rating plate - Example

Fig. 2:

english

Type 6212