Installation, Safety instructions – Burkert Type 6106 User Manual
Page 12
12
Installation
6.5.7. Protection class
Electrical connection
Protection class
without
matching
plug
connector
with
matching
plug
connector
Appliance socket connection in
accordance with DIN 43650 form C
IP20
IP65
Circular plug connection M8, 3-pole
2 pressed-in single wires 0.2 mm
2
(AWG 24)
IP65
-
Rectangular plug connection, 2-pole
IP20
IP20
Rectangular plug connection, 2-pole
without protective collar
7.
INSTALLATION
7.1.
Safety instructions
DANGER!
Danger of explosion!
The device is a closed system. It must not be removed.
Risk of electric shock!
• Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
• Live terminals in the terminal box may cause an electric shock,
short-circuit or explosion. Switch off the power supply. Only then
open the terminal box.
• The connection lines of the electromagnets must be permanently
installed in such a way that they are adequately protected from
mechanical damage.
• Observe applicable accident prevention and safety regulations
for electrical equipment!
WARNING!
Danger – high pressure!
When reaching into the system, there is an acute risk of injury.
• Before dismounting pneumatic lines and valves, turn off the pres-
sure and vent the lines.
• During the installation, make certain the flow direction is correct.
• Observe applicable accident prevention and safety regulations
for pressurized devices.
english
PTB 01 ATEX 2175