Technical data

6.5.5. Safety data

Group:

II C

Ignition protection type:

Ex ia

Temperature class:

T4, T5 or T6

Max. permitted input voltage (U

i

):

35 V

Max. permitted input current (I

i

):

0.9 A

Inductance (L

i

):

~ 0

Capacity (C

i

):

~ 0

The maximum permitted voltages and the associated short-
circuit currents can be found in Table A1 in the standard EN
60079-11 for the corresponding gas group.

Ignition protection type Ex ia II C: Coil Type AC21 (example):

U

i

15

18

20

22

25

28

30

35

I

i

0.9

0.44

0.309 0.224 0.158

0.12

0.101 0.073

The coils of type AC21 are available in two versions:
• Version for use with 300 Ω supply module (300 Ω barrier),
• High-resistance version for use with other authorized supply

modules (e.g. 8 x remote I/O from Stahl).

Version

Resis-

tance

R20 [Ω]

Minimum
clamping

voltage

[V]

Minimum

current

[mA]

Type

Version which
uses 300 Ω
supply module

320

9.3

29

EX I / 21

High-resistance
version

475

10.9

23

EX I / 22

Version for Type
8650

125

6.1

49

EX I / 23

The maximum voltage and current values are specified by
the permitted electrical equipment.

6.5.6. Permitted ambient temperature

The maximum permitted ambient temperature depends on
the power fed in, the temperature class and the installation.
For the appropriate values see chapters “6.5.2” “6.5.3” and
“6.5.4”

.