Assembly

stainless steel insert (only for units without diaphragm and
casing):
A VA insert (order no. 648 864) is enclosed with a device which is
supplied without a diaphragm and body.

use of an epdm / Fkm diaphragm:

When installing a device with elas-
tomer diaphragm (EPDM / FKM),
insert the VA insert into the groove
of the pressure piece.

use of a ptFe - diaphragm:

When using a PTFE diaphragm,
the insert is not required.

insert

6.3.2 connection of the control medium

control function a:

Connect control medium to lower connection.

control function b:

Connect control medium to upper connection.

control function i:

Connect control medium to upper and lower connections
(see „Fig. 7: Control air connection“).

Pressure on the upper connection closes the valve.

Pressure on the lower connection opens the valve.

6.4 maintenance work

6.4.1 actuator

The actuator of the diaphragm valve is maintenance-free provided it is
used according to these operating instructions.

6.4.2 Wearing parts of the diaphragm valve

Parts which are subject to natural wear:
• Seals

• Diaphragm

If leaks occur, replace the particular wearing part with an appro-

priate spare part.

For the maintenance and repair instructions see operating
instructions (DN65 - DN100) on the Internet at:

www.burkert.com

A distended PTFE diaphragm may reduce the flow-rate.

6.4.3 inspection intervals

Check diaphragm for wear after a maximum 10

5

switching

operations.

Muddy and abrasive media require correspondingly shorter
inspection intervals!