beautypg.com

Maintenance and troubleshooting, 10 maintenance and troubleshooting – Burkert Type 1062 User Manual

Page 35

background image

35

Maintenanceandtroubleshooting

Type 1062

Target of the valve
open switch

Activate the valve
so that it opens
completely.

T h e t o p c a m
should be located
o p p o s i t e t h e
target of the valve
open switch.

Target of the valve
closed switch

Activate the valve
so that it closes
completely.

The bottom cam
should be located
o p p o s i t e t h e
target of the valve
closed switch.

Fig. 18: Correct position of the cams in relation to the switches

10

mAinTenAnce AnD
TRoubleshooTinG

10.1 safety instructions

danger

Danger due to high pressure in the installation.

▶ Shut down the pneumatic power source and depressurise the

pipes before carrying out work on the device.

Risk of injury due to electrical discharge.

▶ Shut down the electrical power source of all the conductors and

isolate it before carrying out work on the system.

▶ Observe all applicable accident protection and safety regula-

tions for electrical equipment.

Warning

Risk of injury due to non-conforming maintenance.

▶ Maintenance must only be carried out by qualified and skilled

staff with the appropriate tools.

▶ Guarantee a set or controlled restarting of the process, after a

power supply interruption.

10.2 cleaning of the transmitter

The external surface of the electrical position feedback can be
cleaned with a cloth dampened with water or a product compatible
with the materials from which it is made.

english

This manual is related to the following products: