Wiring a version with inductive 3-wire switch – Burkert Type 1062 User Manual
Page 31

31
Installationandwiring
Type 1062
8.2.3 Wiring a version with inductive
3-wire switch
+
-
A
+
-
200 mA max.
+ -
1062
10-30 VDC
250 mA
Power supply
Load
Reaction speed according
to the max. load
Green light (valve open detection) or red
light (valve closed detection)
Orange light
(voltage present)
Fig. 13: Wiring a version with an inductive 3-wire switch in PNP
mode, valve open or valve closed detection
8.2.4 Wiring a version with two inductive
3-wire switches
+
-
A
+
-
200 mA max.
+ -
1062
10-30 VDC
500 mA
+
-
A
200 mA max.
+ -
Power supply
Load 1
Reaction speed according
to the max. load
Green light (valve open
detection)
Orange light
(voltage present)
Load 2
Valve open
switch
Valve closed
switch
Red light (valve closed
detection)
Fig. 14: Wiring a version with two inductive 3-wire switches in
NPN mode, valve open and valve closed detection
english