Burkert Type 1062 User Manual
Page 18

18
Assembly
Type 1062
D
J
E
H
→
Check that the seal "H" is fitted and
that it is correctly positioned inside
the actuator.
→
Insert the duplication system "D" into
the actuator.
→
Screw the duplication rod "E" onto
the actuator rod "J".
→
Tighten the adaptor until free contact
is obtained with the top of the
actuator, using a flat No 27 spanner.
E
→
Check that the seals have been fitted
and that they are undamaged. Replace
them if necessary.
→
Put thread lock into the internal thread
in the duplication rod "E".
F
G
→
Unscrew the small transparent cap "F"
on the actuator, preferably by hand or
using a suitable tool in order not to
damage it (except for actuators size
40mm).
→
Pump air into the actuator on a valve
which is normally closed (function "A")
or has a double effect (function "I") so
that the actuator rod moves to the top
position.
→
Unscrew the visual position feedback
"G" using a hexagonal male spanner.
english