Technicaldata
Type 1062
Version with inductive
2-wire switch (per
switch)
• Power supply
• Power consumption
• Allowable load
• Type of output
• 10-30 V DC
• ≤ 2 mA
• ≤ 100 mA
• contact normally open or normally
closed
Version with inductive
3-wire switch (per
switch)
• Power supply
• Power consumption
• Allowable load
• Type of output
• 10-30 V DC
• ≤ 25 mA
• ≤ 200 mA
• NPN or PNP, normally open or nor-
mally closed
Version with double
inductive 4-wire switch
• Power supply
• Power consumption
• Allowable load
• Type of output
• 10-30 V DC
• ≤ 15 mA
• ≤ 150 mA, per output
• PNP, normally open
Version with double
inductive 2-wire
NAMUR switch
• Power supply
• Power consumption
• Allowable load
• Type of output
• 8 V DC
• ≤ 1,2 mA (activated) and
> 2,1 mA (not activated)
• see table in chap. „8.2.5“
• acc. to NAMUR
supply voltage
inductive load
[i
max
]
Resistive load
[i
max
]
24 V DC
5 A
5 A
30 V DC
2 A
5 A
50 V DC
0,7 A
1 A
74 V DC
0,25 A
0,6 A
125 V DC
0,03 A
0,4 A
250 V DC
0,02 A
0,25 A
125 V AC
8 A
8 A
250 V AC
8 A
8 A
Table 1: Allowable loads for a mechanical contact version