30
Installationandwiring
Type 1062
1062
+
-
NO
NC
+
-
8 A max.
+ -
Red light (valve closed
detection)
Orange light (volt-
age present)
Power supply
1)
Fuse suitable for
the max. load
Load
Fig. 10: Wiring of the contact when normally closed (NC) on a
mechanical contact version, valve closed detection
1)
Use a power supply that matches the data shown on the name plate of the
1062
8.2.2 Wiring a version with inductive
2-wire switch
+ -
+
-
100 mA max.
+ -
1062
10-30 VDC
125 mA
Power supply
Load
Reaction speed according
to the max. load
Fig. 11: Wiring the inductive 2-wire switch in "less common"
mode, open and/or closed valve detection
+ -
+
-
100 mA max.
+ -
1062
10-30 VDC
125 mA
Power supply
Load
Reaction speed according
to the max. load
Fig. 12: Wiring the inductive 2-wire switch in "more common"
mode, open and/or closed valve detection
english