Assembly
Type 1062
→
Fully tighten the duplication rod on
the actuator rod using a screwdriver
with a blade of suitable size.
→
Depressurize the actuator of a valve
which is normally closed (function
"A") or has a double effect (function
"I"): the valve recovers its default
position.
C
D
→
Insert the position feedback housing
into the duplication system "D"
setting the cable gland in the
direction desired and making sure,
on a mechanical contact version,
that you do not damage the contact
levers on the switches.
→
Fasten the housing and the dupli-
cation system by tightening the cone
point set screw "C" using a hex-
agonal male spanner.
K
L
→
Unscrew the cover "K" on the
position feedback.
→
Unscrew the cable gland "L".
→
Thread the cable through the cable
gland.
→
Wire according to the wiring
diagram for your version of the 1062:
See chap. „8 Installation and wiring“
→
Fasten the cable gland to ensure
tightness of the product.
7.4
fitting the position feedback with
stroke limiter to a pneumatic
actuator size 50 to 80mm
note
the tightness of the actuator is not guaranteed when the
transparent cap is removed.
▶ Prevent the projection of fluids into the actuator.
the tightness of the position feedback is not guaranteed
when the cover is removed.
▶ Prevent the projection of fluids into the position feedback.
english