Burkert Type 2012 User Manual
Page 23

23
Conversionofcontrolfunction
Type 2000, 2002, 2012
7.3
conversion from control function a (cfa) to
control function i (cfi)
Danger!
danger – high pressure!
▶ Turn off the pressure and vent the lines before loosening lines or valves.
Risk of injury from improper maintenance!
▶ Maintenance may be performed by authorized technicians only!
▶ To screw on or unscrew valve body or actuator, use an open-end wrench, never a pipe wrench.
▶ Observe tightening torques.
Required parts:
item
description
30
1 O-ring
procedure:
→
Mount valve
1
on the body.
Caution!
danger through taut springs!
▶ Carefully open piston actuator!
→
Release cover
31
with special wrench until the springs are completely relaxed, holding up the actuator body
12
against the hexagon.
For information about the special wrench, see Chapter “8. Installation tools”.
→
for actuator size G (100 mm) and h (125 mm): Remove washer
40
.
→
Remove pressure springs
28
29
.
→
Insert O-ring
30
into the groove of the actuator body.
→
Mount cover
31
and screw tightly with special wrench.
→
Check the valve for function and leaks.
For control function I (CFI) connect both control air connections to the control lines.