conveRsIon fRom flow below the seat

to flow above the seat

DAnGer!

Danger – high pressure!
• Turn off the pressure and vent the lines before loosening lines or

valves.

Risk of injury from improper maintenance!
• Maintenance may be performed by authorized technicians only!
• To screw on or unscrew valve body or actuator, use an open-end

wrench, never a pipe wrench, and observe tightening torques.

Required parts:

Item

Description

28, 29

2 Pressure springs for actuator C (40 mm),

D (50 mm), E (63 mm), F (80 mm)

Procedure:

Mount valve

1

on the body.

CAutIon!

Danger through taut springs!
• Carefully open piston actuator!

Release cover

31

with special wrench until the springs are

completely relaxed, holding up the actuator body

12

against the

hexagon.

For information about the special wrench, see Chapter
“Installation tools”.

Remove and / or insert pressure springs

28

29

depending on

actuator.

For actuator size C (40 mm), D (50 mm), E (63 mm) and
F (80 mm): Remove pressure springs and insert new, weaker
springs.

For actuator size G (100 mm) and H (125 mm): Remove outer
spring only

29

, inner spring

28

remains in the actuator.

Mount cover

31

and screw tightly with special wrench.

Check the valve for function and leaks.

Note changed direction of flow and changed pressure range!

English

InstallatIon tools

Installation wrench for actuator C (40 mm) and D (50 mm)

Actuator

ø (mm)

Order no.

C

40

639 175

D

50

639 175

Installation wrench for actuator E (63 mm)

Actuator

ø (mm)

Order no.

E

63

639 170

Installation wrench for actuator F (80 mm), G (100 mm) and

H (125 mm)

Actuator

ø (mm)

Order no.

F

80

639 171

G

100

639 172

H

125

639 173

English