4. Zone supply


Up to five Junction boxes can be connected in both directions from a Control box.

The Zone supply conductor runs from the Control box and through the Junction boxes.
The conductor cable area must be 2.5mm

2

. The integrator is responsible for the choice of

Zone supply conductor and wiring way.

Note: Preferably U.I. Lapp, Ölflex 110, 5G2.5, 1119 405, is selected for european
installations.

WARNING! Disconnect electrical power by switching off the main switch of the Control box
before any electrical installation is started. Lock the switch with a padlock until the
installation is finished.

• Run the conductor from the Control box and connect it to nearest Junction box.
• Continue to run conductors between the rest of Junction boxes.


Junction box

Control box

Cable area = 2.5mm

2