7. Feedback functionality – Track width setting
7.1 System overview
The home position sensor (1) and the pulse sensor (2) shall be connected to the field bus
interface in the Control box with a cable (not included in delivery). The cable must have M8
3-pin connector towards the sensors.
The pulse sensor (2) is a magnetic sensor that counts pulses while the screw (3) is
rotating. The home position sensor (1) is a inductive sensor that detects when the sliding
element (4) is in end position.
7.2 Synchronization
If, by any reason the Guide units in a line are in different positions the line has to be
synchronized. When the command “synchronize” is chosen the unit starts to move out.
After reaching the home position sensor (1) the unit continues to move another 20
seconds*. If needed repeat this sequence until all Guide units are in outer position.
*The Guide unit can run against mechanical stop. This will make a humming sound but will
not damage the motor inside.
For controls information see document "Software user guide".