Numeric Value Entry Procedure
Note: If you are already in PROGRAM mode and the selection to
be viewed or changed is already displayed, proceed to step 3
below. If you are in PROGRAM mode and the selection to be
viewed or changed is not displayed, press the
▲
or
►
arrow keys
and repeat pressing until the desired selection appears. Proceed
to step 3.
1. Press MENU key.
2. Press the
►
arrow key to move to the desired selection. The
current numeric value for this selection appears on the upper
line of the display.
3. If the current value is desired, press ENTER. The left most
programmable number begins to flash. Press ENTER again to
confirm and keep the current numeric value. The unit will
automatically advance to the next menu selection.
4. If the current selection must be changed, press ENTER. The
left most programmable number begins to flash. Use the
▲
arrow key to scroll through the digits 0-9 and change the
flashing digit to the desired value. Use the
►
arrow key to
move the active digit to the right. Continue using the
▲
and
►
arrow keys until all digits are selected.
5. Press ENTER to confirm your selection. The unit will automatically
advance to the next selection.
6. To exit PROGRAM mode, press the MENU key. Depending on
your position in the PROGRAM mode, up to three MENU key
presses may be required to exit. The display will change to
RUN mode.
Resetting the Flow Totalizer
Press both the ENTER and the MENU keys when in the RUN mode
to reset the totalizer. The message TOTAL RST will be displayed
for a few seconds to indicate that the totalizer had been cleared.
If a password has been set, the user must enter the correct
password for the totalizer to be cleared.
Basic Menu Items
The Basic Menu contains standard configuration items that are
utilized to setup a FUSION flow meter in common applications.
The following items are available for viewing and modification in
the Basic Menu: