ALLIED Vision Technologies Goldeye P-032 SWIR User Manual

Page 35

background image

Display camera live images

How to install a GigE camera (Bigeye/Pearleye/Goldeye) V2.1.0

35

all NI applications and delete all files and folders within the following
directory:

C:\Documents and Settings\All Users\Documents\National Instruments\NI-
IMAQdx\Data

When you want to switch between a GigE Vision application (e.g. NI MAX)
and an iPORT application (e.g. Coyote), it is necessary to power cycle the
camera.

In some situations the MAX software is not able to confirm the used pixel
format. In this case open the Acquisition Attributes tab and reselect the
desired Pixel Format.

The default setting for the packet size of the NI MAX software is 8000
bytes. If your network card can’t handle packets of this size, check the
Jumbo Frames settings of your network adaptor (see Chapter

Performance

optimization

on page 36) or reduce the packet size in

NI MAX ( Acquisition Attributes  Packet Size).