Physical Data

Notes:
1. Ratings in accordance with AHRI Standard 550/590.
͖Ǥ ‘ƒ‰‡”ƒ–‹‰•…‘†‹–‹‘•ǣ͘͘η Ž‡ƒ˜‹‰…Š‹ŽŽ‡†™ƒ–‡”–‡’‡”ƒ–—”‡ǡ͙͜η ‡–‡”‹‰…‘†‡•‡”™ƒ–‡”–‡’‡”ƒ–—”‡ǡƪ‘™”ƒ–‡•ƒ”‡͗‰’’‡”

ton through the condenser with a fouling factor of .00025 hr-ft2-°F/Btu and 2.4 gpm per ton through the evaporator with a .0001 hr-ft2-°F/Btu
fouling factor.

3. Module operational weight includes water, compressor oil, and refrigerant charge. Multiply times the number of modules for a total system

operational weight.

4. Unit shipping weight includes refrigerant charge, compressor oil and packaging.
͙Ǥ ƒ‹Š‡ƒ†‡”™ƒ–‡”Ȁƪ—‹†…‘‡…–‹‘•ƒ”‡͚dz‰”‘‘˜‡†…‘—’Ž‹‰ˆ‘”–Ї͔͗ǡ͙͔ƒ†͔͛–‘‘†—އ•ǤЇ͙͜–‘‘†—އ—•‡•͜dz‰”‘‘˜‡†

couplings.

͚Ǥ ͙͜–‘‘†—އ…ƒ‘–„‡†‹”‡…–Ž›…‘—’އ†™‹–Š͔͗ǡ͙͔‘”͔͛–‘‘†—އ•†—‡–‘ƒ†‹ơ‡”‡…‡‹Š‡ƒ†‡”ƒ†ˆ”ƒ‡•‹œ‡Ǥ
͛Ǥ ‡“—‹”‡†–‘’”‘˜‹†‡•–ƒ„އ‘’‡”ƒ–‹‘Ǥ–‘”ƒ‰‡Ȁ„—ơ‡”–ƒ•ƒ›„‡—–‹Ž‹œ‡†‹”‡–—”’‹’‹‰–‘‡‡––Ї‹‹—˜‘Ž—‡”‡“—‹”‡‡–•Ǥ

30

50

70

85

31.7

51.5

67.2

82.8

0.738

0.746

0.744

0.740

16.3

16.1

16.1

16.2

2

2

2

2

Scroll

Scroll

Scroll

Scroll

2

2

2

2

15

25

35

40

15

32

34

40

1480

2200

2450

2855

1290

1880

2130

2390

30

50

70

85

Brazed Plate

Brazed Plate

Brazed Plate

Brazed Plate

2

2

2

2

3.2

6.1

7.3

11.4

13.1

16.7

17.9

26.2

Min

180

300

420

510

300

300

300

300

6

6

6

8

30

50

70

85

Brazed Plate

Brazed Plate

Brazed Plate

Brazed Plate

2

2

2

2

2.8

5.1

6.5

9.7

12.8

15.7

17.1

24.5

Min

180

300

420

510

300

300

300

300

6

6

6

8

Compressor Quantity

Compressor Nominal Hp (per circuit)

Refrigerant Charge (per circuit) R-410A (lbs)

Module Operating Weight w/Water (lbs)

3

Model UCH Module and Compressor

Capacity (tons)¹

kW/Ton

Full-Load EER

2

Compressor Type

Refrigerant Circuits (quantity)

Model UCH Condenser

Heat Exchanger (type)

Independent Refrigerant Circuits (quantity)

Water Storage Volume HX Only (gals)

Module Shipping Weight (lbs)

4

Model UCH Evaporator

Header Water Connections - Inlet/Outlet (inches)

5

Maximum Design Working Pressure - Water Side (psi)

System Volume (gals)

7

Maximum Design Working Pressure - Water Side (psi)

System Volume (gals)

7

Water Storage Volume HX Plus 6" Main Headers (gals)

Heat Exchanger (type)

Water Storage Volume HX Only (gals)

Independent Refrigerant Circuits (quantity)

SHC onDEMAND®

Water Storage Volume HX Plus Main Headers (gals)

Header Water Connections - Inlet/Outlet (inches)

5

1850

1530

2150

2400

2850

2460

2710

3350