Project Name:

Contractor Name:

PID Interval

PID Interval

Use Pre-calc PID Values Below?

Use Pre-calc PID Values Below?

Stage One Cool PID P-Gain

Stage One Heat PID P-Gain

Stage One Cool PID I-Gain

Stage One Heat PID I-Gain

Clg PID Rise

Htg PID Rise

Clg PID Fall

Htg PID Fall

Or Manually Select PID Values Below

Or Manually Select PID Values Below

Stage One Cool PID P-Gain

PID P-Gain

Stage One Cool PID I-Gain #1

PID I-Gain #1

Clg PID Rise

Htg PID Rise

Clg PID Fall

Htg PID Fall

Max Cool Ramp Rate

Max Heat Ramp Rate

Use Max Possible Compressors

Heat Max PID Limit w/MVlv

Cool Max PID Limit w/MVlv

Max PID of Last Stage w/MVlv

Max PID of Last Stg w/MVlv

PID Switching Differential

Cool DB 1

Heat Cnt Setpoint Offset

Cool DB 2

Heat DB 1

Stage one Cool PID I-Gain #2

Heat DB 2

PID Switching Differential

Stage one Heat PID I-Gain #2

Cool Cnt Setpoint Offset

Use Channel #8 as Diff Pressure Sensors?

Cool Water In Low Limit

Use High Range Differential Pressure Sensors?

Cool Water In High Limit

+LJK5DQJH SVLG/RZ5DQJH SVLG

Cool Water Out Low Limit

Source Water Minimum Differential Flow Setpoint

Cool Water Out High Limit

Cond Water Minimum Differential Flow Setpoint

Heat Water In Low Limit

Chilled Water Minimum Differential Flow Setpoint

Heat Water In High Limit
Heat Water Out Low Limit

Pressure Relief Valve Installed?

Heat Water Out High Limit

Discharge Pressure Alarm Setpoint

Outdoor Air Low Limit

High Suction Pressure Alarm

Outdoor Air High Limit

High Discharge Temperature Alarm

Source Water In Low Limit

Mod extra Low suction pressure Alarm

Source Water In High Limit

Mod Suction Press Time Delay before Alarm

Source Water Out Low Limit

Heat Low Suction Temp Alarm

Source Water Out High Limit

Cool Low Suction Temp Alarm

Freeze Target Setpoint FN6

Heat Low Suction Pressure Alarm
Cool Low Suction Pressure Alarm

Module Cool Evap Water Out Low Limit
Module Cool Evap Water Out High Limit

Module Low Discharge Superheat

Module Cool Cond Water Out Low Limit

Module Low Suction Superheat

Module Cool Cond Water Out High Limit

Module High Suction Superheat

Module Heat Evap Water Out Low Limit
Module Heat Evap Water Out High Limit
Module Heat Cond Water Out Low Limit
Module Heat Cond Water Out High Limit

Loadside loop valves installed? How Many?

Building Water Loop Type

Chiller Header Bypass Valves Installed?
Percentage of Glycol in Each Loop

Chilled Condenser Source

2 WAY VLVS 3 WAY VLVS

Channel 8 & 11 Setup FN8

CoolLogic

Water & Air Temp Limits FN8

PID SETTINGS

HEATING PID

COOLING PID

Module Water Temp Limits FN6

Suction & Disch Superheat Alarm Setpts FN6

Refrig Temp & Pressure Alarm Settings FN6

Compressor Min. & Max Run Times FN6

Compr. Min. ON Time Compr. Min. OFF Time