Press
on the data setting screen.
The wheel balancing machine can be used simultaneously
by 4 different users who, through a simple sequence, can
memorize their work condition and call it when needed. The
names of the users can be stored (
PRESETTING CLIENT
AND USER NAMES
).
selecting the user to call up and program
recalling the selected user
The system automatically returns to the initial screen with
recalculation of the unbalance values on the basis of the
effective dimensions of the USER called.
The dimensions memorized as USER are lost when the
machine is switched off;
The current USER is always displayed in the Measure-
ments and Dimensions screens.
programming the selected user
INDICATION
Remember to set correctly the dimensions in the manner
already decribed in the paragraph “PRESETTING OF
WHEEL DIMENSIONS”.
Use of the wheel balancer
5.5 RESULT OF MEASUREMENT
After positioning and locking the wheel, apply the weight
vertically at the top. When the beep signal is enabled (
ACOUSTIC SIGNAL
), reaching of the correction position is
accompanied by a “beep”. If the out-of-balance is less than
the chosen threshold value, “0K” appears instead of the
out-of-balance value to indicate, on that particular side, that
the wheel is in tolerance; the residual out-of-balance can be
displayed by pressing the button
, with an accuracy
of 0.5 g (0.1 oz.)
The following buttons are enabled:
display of residual out-of-balance.
selection of correction mode (STATIC/DUAL
SURFACE). When the mode is changed, the
unbalance values are recalculated automati
cally on the basis of the previous spin.
Simultaneous display of the dynamic+static
unbalance can be enabled through the special
function in Setup (see par.
STATIC ALWAYS
ENABLED
).
prints the balancing certifi cate (option)
eccentricity measurement graph (OPTIONAL).
N.B
:
1. The symbol above the key is displayed
in yellow if the fi rst harmonic eccentricity
exceeds the limit set in the setup parameters
(
FIRST HARMONIC LIMIT
).
2. When this push button is held down for more
than 1.5 seconds, eccentricity measurement is tem-
porarily disenabled (enabled in
SETUP
). To re-ena-
ble eccentricity measurement, press push button
[4] again for more than 1.5 seconds. Every time the
machine is switched on, the status of eccentricity
measurement refl ects the settings in
SETUP
.
Inside unbalance
indicator
Outside unbalance
indicator
Static unbalance
indicator
SONAR STATUS RADIAL
ECC. (eccentricity)
SONAR STATUS
LATERAL ECC.
SONAR STATUS:
GREEN: in measuring position