beautypg.com

4 user control, 5 result of measurement – CEMB USA C88 EVO (C) User Manual

Page 14

background image

14

1

2

3

1

2

3

Use and maintenance manual Rev. 02-2010

ENGLISH

5.4 USER CONTROL

Press

on the data setting screen.

The wheel balancing machine can be used simultaneously
by 4 different users who, through a simple sequence, can
memorize their work condition and call it when needed. The
names of the users can be stored (

PRESETTING CLIENT

AND USER NAMES

).

selecting the user to call up and program

recalling the selected user

The system automatically returns to the initial screen with
recalculation of the unbalance values on the basis of the
effective dimensions of the USER called.

The dimensions memorized as USER are lost when the

machine is switched off;

The current USER is always displayed in the Measure-

ments and Dimensions screens.

programming the selected user

INDICATION

Remember to set correctly the dimensions in the manner
already decribed in the paragraph “PRESETTING OF

WHEEL DIMENSIONS”.

Use of the wheel balancer

5.5 RESULT OF MEASUREMENT

After positioning and locking the wheel, apply the weight
vertically at the top. When the beep signal is enabled (

ACOUSTIC SIGNAL

), reaching of the correction position is

accompanied by a “beep”. If the out-of-balance is less than
the chosen threshold value, “0K” appears instead of the
out-of-balance value to indicate, on that particular side, that
the wheel is in tolerance; the residual out-of-balance can be

displayed by pressing the button

, with an accuracy

of 0.5 g (0.1 oz.)

The following buttons are enabled:

display of residual out-of-balance.

selection of correction mode (STATIC/DUAL

SURFACE). When the mode is changed, the

unbalance values are recalculated automati

cally on the basis of the previous spin.

Simultaneous display of the dynamic+static

unbalance can be enabled through the special

function in Setup (see par.

STATIC ALWAYS

ENABLED

).

prints the balancing certifi cate (option)


eccentricity measurement graph (OPTIONAL).

N.B

:

1. The symbol above the key is displayed

in yellow if the fi rst harmonic eccentricity

exceeds the limit set in the setup parameters

(

FIRST HARMONIC LIMIT

).

2. When this push button is held down for more

than 1.5 seconds, eccentricity measurement is tem-

porarily disenabled (enabled in

SETUP

). To re-ena-

ble eccentricity measurement, press push button

[4] again for more than 1.5 seconds. Every time the

machine is switched on, the status of eccentricity

measurement refl ects the settings in

SETUP

.

Inside unbalance

indicator

Outside unbalance

indicator

Static unbalance

indicator

SONAR STATUS RADIAL

ECC. (eccentricity)

SONAR STATUS

LATERAL ECC.

SONAR STATUS:

GREEN: in measuring position

RED: out of measuring range