Diagnostics
9. diagnostics
WARNING
T
he
INfoRmATIoN
IN
The
possIble Remedy
columN
RequIRes
WoRK
To
be
peRfoRmed
by
specIAlIsT
TechNIcIANs
oR
oTheR
AuThoR
-
Ised
people
Who
musT
AlWAys
WoRK
usING
The
p
eRsoNAl
p
RoTecTIve
e
quIpmeNT
INdIcATed
IN
The
INsTAllATIoN
mANuAl
. I
N
some
cAses
,
ThIs
WoRK
cAN
be
peRfoRmed
by
A
NoRmAl
opeRAToR
.
SoFtwarE
ErrorS
caUSE
poSSIBLE rEMEdY
Black
The wheel balancing machine does not
switch on.
1. Check the machine is properly connected to the mains power supply.
2. Check the fuses on the power board and replace if necessary.
3. Check display functioning.
4. Replace the PC.
Err. 1
STOP button pressed with the motor
running.
1. Reset the error.
2. Repeat the spin.
Err. 2
Speed too low during measurement.
During the unbalance measurement
spins, the wheel speed dropped to
below 42 rpm.
Make sure that a vehicle wheel is mounted on the wheel balancing
1.
machine.
Use the self-diagnostics function to check the encoder.
2.
Disconnect the measuring head connector from the board and perform
3.
a spin (if there is no error, replace the measuring heads)
Replace the computer board.
4.
Err. 3
Unbalance too high.
1. Check the wheel dimensions setting.
2. Check the detection unit connections.
3. Run the machine calibration function.
4. Mount a wheel with a more or less known unbalance (definitely less
than 100 grams) and check the response of the machine.
5. Replace the computer board.
Err. 5
Guard open.
Guard opening during the measuring
cycle
1. Reset the error
2. Check functioning of the protection switch
3. Close the guard.
Err. 6
Spindle open
Spin enabled without first having closed
the spindle.
1. Reset the error
2. Close the spindle
3. Lower the guard
Err. 8
Error in transfer of the outside profile
measurement data from the computer
board to the PC.
1. Repeat the outside profile measurement.
2. Replace the computer board.
Err. 9
Error in transfer of the inside profile
measurement data from the computer
board to the PC.
1. Repeat the inside profile measurement.
2. Replace the computer board.
Err. 10
The inside adhesive weight distance is
greater than the outside adhesive weight
distance.
1. Repeat the wheel dimension measurement.
2. Repeat the laser calibration function.
3. Replace the computer board.
Err. 11
Speed too high error.
During unbalance measurement rota-
tion, wheel speed is more than 270 rpm.
1. Use the self-diagnostics function to check the encoder.
2. Replace the computer board.
Err.15
Error. Dimensions stored invalid
1. Repeat the wheel dimension measurement.
2. Use the self-diagnostics function to check proper functioning of the
lasers.
3. Replace the computer board
Err. 16
Internal laser position error during the
machine calibration function.
1. Check that the internal laser is in the rest position.
2. Use the self-diagnostics function to check proper functioning of the
internal laser.
3. Check proper functioning of the switch that detects the internal laser
in rest position.
4. Access the machine calibration function with the laser only