beautypg.com

Specifi cations and data – C.E. Niehoff & Co. C130/C131/C132 Inst/Parts Rep/TG Combo Guide User Manual

Page 11

background image

Page 11

SM40A

Specifi cations and Data

C130/C131/C132

ALTERNATOR

MODEL

VOLTS

C130/C130-1/

C130-4/C130-5

C130-3

C131/C131-1/

C131-2

C131-3

C132/C132-1

60

60

70

70

60

ALT.

WEIGHT

kg/lb

24

24

14

14

28

AMPS

Steps

Settings

Model

A2-139

A2-161

A2-152

A2-162

A2-139

N/A

N/A

N/A

N/A

N/A

28.0

27.6

14.2

13.8

28.0

10.17/22.4

10.17/22.4

10.17/22.4

10.17/22.4

10.17/22.4

REGULATOR

1. Measurements are taken at the listed ambient

temperature and a stabilized machine tempera-
ture at maximum output with voltage constant
as specified.

2. The alternator has an isolated ground.
3. Temperature compensation—see definition below.

NOTES

1680

1680

980

980

1680

WATTS

Temp. Comp.(4)

Flat

Flat

Flat

Flat

Flat

Flat temperature compensation: Regulator controls

voltage range in a near-constant state during the
vehicle operating conditions. CEN flat-temperature
compensated regulators have preset voltage setpoints.

Setpoint: Voltage value to which regulator is set.

Voltage value is established by battery type and
vehicle duty cycle. Setpoint value is fixed (flat com-
pensation).