beautypg.com

C.E. Niehoff & Co. A8-128 Power Management System Installation User Manual

A8-128 power management system, Installation instructions

background image

INSTALLATION

1. A8-128 Power Management System should be

installed as close to the main battery compartment

as possible to minimize the effect of voltage drops

along power cables. The PMS is grounded to its case

and will require external grounding by installing

directly on grounded chassis (connected to battery

ground) or direct grounding through properly sized

cable installed on one of the six screws holding the

PMS to chassis and then connected directly to the

battery ground. See below for stacking order and

torque.

Make sure cables are properly sized and

supported within 305mm/12 in. of PMS.

Failure to do so can cause component

damage.

2. Cable connections (see below for stacking order and

torque):

a. Connect "MAIN" cable from "MAIN" terminal on

PMS to either the alternator output cable or posi-
tive terminal of the "Main" (engine starter) battery.
See below for stacking order and torque on PMS
"MAIN" terminal. Make sure the LED located next to
the terminal remains visible after cable is connected.

Make sure cables are properly sized and

supported within 305mm/12 in. of PMS.

Failure to do so can cause component

damage.

Page 1 of 1

II201A

A8-128

Power Management System

Installation Instructions

Figure 1 – A8-128 Power Management System (PMS)

If you have questions about your alternator or any of these instructions, or if you need to locate a Factory Authorized Service Dealer, please contact us at:

C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA

TEL: 800.643.4633 USA and Canada • TEL: 847.866.6030 outside USA and Canada • FAX: 847.492.1242

E-mail us at [email protected]

Mounting hardware

(6 places)

torque to

8.5 Nm/75 lb. in.:

M5x16mm screw,

Belleville washer

Ground terminal (when used)

LED

This symbol is used to indicate the presence

of hazards that can cause minor personal

injury or equipment damage.

CAUTION

b. Connect "AUX" cable from "AUX" terminal on PMS to

either an auxiliary load or the positive terminal of
an Auxiliary Battery system.

Make sure cables are properly sized

and supported within 305mm/12 in.

of PMS. Failure to do so can cause

component

damage.

3. Schematic diagram is shown below.
4. Test all components to make sure they operate properly.

A8-128 SYSTEM OPERATION

A8-128 Power Management System (PMS) is programmed

to automatically connect the "MAIN" source positive

polarity (B+) to the positive polarity "AUX" battery or

loads. The PMS automatically disconnects the "AUX"

from "MAIN" if an overload condition occurs. The PMS

functions as both battery isolator and automatic load

switching system.

CAUTION

CAUTION

CAUTION

LED COLOR

STATUS

A8-128 LED Status

No power present on "MAIN" terminal.

OFF

Power of "MAIN" terminal appears at
"AUX" terminal (switch is closed).

GREEN

Power of "MAIN" terminal does not
appear at "AUX" terminal (switch is
open). Normally due to an overload
condition that caused switch to open.
PMS automatically resets by resolving
cause of overload condition.

AMBER

"MAIN" terminal torque

to 15 Nm/11 lb. ft.:

M10x1.5 bolt,

Lock washer

Washer

"MAIN" cable terminal

"AUX" terminal torque

to 15 Nm/11 lb. ft.:

M10x1.5 bolt,

Lock washer

Washer

"AUX" cable terminal