beautypg.com

C.E. Niehoff & Co. A2-317 Regulator Installation User Manual

Conversion instructions

background image

II0132A

Page 1 of 1

Converting A2-317 Regulator

to A2-330 Remote-Mounted Regulator

with C803 Alternator on LA Metro Buses

Conversion Instructions

1. Disconnect battery master switch.
2. Identify and mark wires at regulator IGN,

P (when applicable), and D+ terminals.

3. Cut wires at IGN, P (when applicable), and D+

terminals on regulator close to the terminals.

4. Remove regulator mounting hardware.
5. Remove regulator harness from regulator and

remove

regulator.

6. Strip 1/4" insulation from previously cut wires

that connected to IGN, P (when applicable), and

D+ regulator terminals.

7. Crimp extension harness pigtail connector wires:

green to IGN terminal wire, brown to P terminal

wire (when applicable), and white to D+ terminal

wire.
8. Connect extension pigtail to extended harness

assembly and connect regulator connector to the

regulator harness at alternator, tighten securely.

9. Route the extension harness along existing

harness in engine compartment above air filter

housing to air intake manifold on side of vehicle.

10. Using P clamps and properly sized wire ties,

secure the new harness where appropriate.

11. Secure regulator end of harness to a vertical pipe

near air intake duct with P clamps.

12. Set replacement regulator setpoint to required

voltage (copy setting from existing regulator).

13. Mount regulator to air intake manifold using

self-tapping screws with connector on regulator

positioned at 12 o'clock (pointing up).

14. Connect extension harness to regulator, tighten

securely.
15. Connect IGN, P (when applicable), and D+

terminal wires to regulator.

16. Connect battery master switch.
17. Start vehicle and verify charge voltage setpoint,

harness routing, and harness support.

Buses 9500-up late style have IGN, D+, and P terminal wires attached to regulator.
A three-wire harness assembly and pigtail will be provided.

Buses 9200-9400 early style have ONLY the IGN and D+ terminal wires attached to regulator.
P terminal is empty. A two-wire harness assembly and pigtail will be provided.

Extension harness pigtail connector

with shrink sleeves

V

Harness includes 20 A slow-blow fuse
(Bussman MDA20 or equiv.)
in each fuse holder

V

Step 15: White wire from pin B
to D+ terminal on regulator—
torque to 4.5 Nm/40 lb. in.

Step 15: Green wire from pin A

to IGN terminal on regulator—

torque to 4.5 Nm/40 lb. in.

V

4 places—5mm x 0.8 screws

and disc spring washers

torque to 8.5 Nm/75 lb. in.

V

Figure 1 – Remote Mounted A2-330 Regulator with Extended Wire Harness Assembly

V

P terminal

Diagnostic LED

V

W

Step 15: When applicable,
brown wire from pin C
in 3-pin connector
to P terminal on regulator—
torque to 4.5 Nm/40 lb. in.

V

Step 7: When applicable,

brown wire (Pin C)

to P terminal wire

Step 7: White wire (Pin B)
to D+ terminal wire

Step 7: Green wire (Pin A)

to IGN terminal wire

Connect

this end to

regulator harness

at alternator

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633