PA Industries Edge Sequential Servo Roll Feed SRF-100/125/200/300/400/500/600 - Operation Manual User Manual
Page 9

ULTRA EDGE SEQUENTIAL 6
/05/2002
9
Length is a distance in inches (or millimeters) of the “Feed Length”. It is a numeric entry with a range of 0 to the
999999.
Gags is a combination of the outputs that are activated (fired) at the step. It is a binary entry. Five digits represent five
outputs, starting from the right, 0 represents inactive output, 1 - active.
T # 1 S # 1 / 2 4
R e p e a t 2
E x i t e d i t i n g <
T O O L S - n e x t B K S P - P r e v
Repeat is the number of times the step must be repeated. It is a numeric entry with a range of 0 to 999.
Exit editing is a command that allows saving the currently edited tool, saving it with a different name, or deleting it
from the drive memory.
NOTE: Up to 200 tools can be saved.
T # 1
S a v e <
S a v e a s
T O O L S - n e x t B K S P - P r e v
Use SAVE to save the tool being edited. Press the “ENTER” key.
T o o l # 1 S a v e d
Use SAVE AS to create a new tool using the settings of the one being edited. Press the “ENTER” key, enter desired
new tool number, and press the “ENTER” key again.
S a v e A s T o o l #
P r e s s T O O L S t o A b o r T
S a v e A s # 1 2 3 4 5 6 7
T o o l # 1 2 3 4 5 6 7 S a v e d
The display will show the FEED STATUS screen.