4 error codes – PA Industries Edge Sequential Servo Roll Feed SRF-100/125/200/300/400/500/600 - Operation Manual User Manual
Page 26

ULTRA EDGE SEQUENTIAL 6
/05/2002
26
5.4 ERROR CODES
Error
Code
Problem or
Symptom
Possible Cause(s)
Action/Solution
04 Motor
Over
Temperature
Motor thermostat trips due to: 
High motor ambient 
temperature, and/or 
Excessive RMS torque. 
Bad encoder cable or 
connection. 
Operate within (not above) the continuous torque rating 
for the ambient temperature (40'C maximum). 
Lower the ambient temperature to increase motor 
cooling. 
Check the encoder cable connections. Check the 
encoder cable for continuity. 
Motor cables shorted.
Verify continuity of motor power cable and connector.
Motor winding shorted 
internally. 
Check for short on U,V,W and Gnd windings of the 
motor. 
Ultra5000 Servo drive 
temperature too high. 
Check for clogged vents or defective fan. 
Ensure cooling is not restricted by insufficient space 
around the unit. 
Operation above continuous 
power rating. 
Verify ambient temperature is not too high (above 60' 
C). Operate within the continuous power rating. 
05 IPM
Fault
Ultra5000 has a bad IPM, 
output short circuit, or over 
current. 
Replace Ultra5000.
Low AC line/AC power input.
Verify voltage level of the incoming AC power.
09
Bus Under Voltage
100 VAC minimum for safe 
Ultra5000 operation. 
Check AC power source for glitches or line drop (below 
90V AC). 
Install an uninterruptible power supply (UPS) of the 
proper size on your AC input. 
Excessive regeneration of 
power. 
When the motor is driven by an 
external mechanical power 
source, it may regenerate too 
much peak energy through the 
Ultra5000's power supply. The 
system faults to save itself from 
an overload. 
Lower the deceleration rate. 
 
Excessive AC input voltage.
Verify input is below 264V AC.
Output short circuit.
Check for shorts.
Motor cabling wires shorted 
together. 
Check for shorts.
10
Bus Over Voltage
Internal motor winding short 
circuit. 
Check for shorts.
Incorrect phasing.
Check cables and connections.
11
Illegal Hall State
Bad connections.
The motor encoder encountered 
an illegal transition. 
Replace the motor. Check the Pilot Release settings. 
Route the cables away from potential noise sources. 
Check the system grounds. 
20 Motor
Encoder
State Error
Bad encoder.
Replace motor.