1 output state, 2 output summing, 3 trigger subsystem – B&K Precision 4079 - Manual User Manual
Page 71: 1 trigger mode

65
Note: For model 4079, nothing changes in the commands above to control channel 1. But for channel 2, change :OUTP
to :OUTP2. For example, to change channel 2 output to ON, send the command: OUTP2 ON or OUTP2 1.
4.13.2.1 Output State
:OUTPut [:STATe]
This command controls whether the output is ON or OFF.
Arguments
Type:
Boolean
Command Type: Setting or Query
Setting
Syntax:
:OUTPut[:STATe]
Examples:
:OUTP:STAT ON
:OUTP OFF
Query
Syntax:
:OUTPut[:STATe]?
Response:
0|1
4.13.2.2 Output Summing
:OUTPut :SUMming
This command controls whether the summing is ON or OFF.
Arguments
Type:
Boolean
Command Type: Setting or Query
Setting
Syntax: :
OUTPut:SUMming
Examples:
:OUTP:SUM ON
:OUTP:SUM OFF
Query
Syntax:
:OUTPut:SUMming?
Response:
0|1
4.13.3 Trigger Subsystem
The Trigger Subsystem is used to control the waveform triggering. The command structure is as follows:
:TRIGger
:MODE CONTinuous|TRIGger|GATE|BURSt
:BURSt
:SOURce :TIMer Note: For model 4079, nothing changes in the commands above to control channel 1. But for channel 2, change :TRIG to :TRIG2. For example, to change channel 2 mode to gate, send the command: TRIG2:MODE GATE. 4.13.3.1 Trigger Mode :TRIGger:MODE