4.13.1.12.1 PULSe PERiod
This command sets the pulse period to the specified value.
NOTE: This also sets the pulse frequency.
Arguments
Type:
Numeric
Units:
S, mS, uS, nS
Range: 40nS-2000S
Rounding:
4 digits
Command Type: Setting or Query
Setting
Syntax:
[:SOURce:] PULse: PERiod
[:SOURce:] PULse: PERiod
Examples:
[:SOURce:] PULse: PERiod 500NS
Query
Syntax:
[:SOURce:] PULse: PERiod?[
Response:
NR3
4.13.1.12.2 PULse WIDth
This command pulse width to the specified value.
Arguments
Type:
Numeric
Units:
S, mS, uS, nS
Range:
20 nS minimum; maximum defined by period and transition (see note above)
Rounding:
4 digits
Command Type: Setting or Query
Setting
Syntax:
[:SOURce:]PULse:WIDth
[:SOURce:] PULse:WIDth
Examples:
[:SOURce:] PULse:WIDth 500NS
Query
Syntax:
[:SOURce:] PULse: WIDth?[
Response:
NR3
4.13.1.12.3 PULse EDGe
This command sets both rising and falling edge of the pulse to the specified value.
Arguments
Type:
Numeric
Units:
S, mS, uS, nS
Range:
100 nS minimum; maximum defined by period and width (see note above)
Rounding:
4 digits
Command Type: Setting or Query
Setting
Syntax:
[:SOURce:] PULse:EDGe
[:SOURce:] PULse:EDGe
Examples:
[:SOURce:] PULse:EDGe 500NS
Query
Syntax:
[:SOURce:] PULse:EDGe?[
Response:
NR3
4.13.1.12.4 PULse RISe
This command sets rising edge of the pulse to the specified value.
Arguments
Type:
Numeric
Units:
S, mS, uS, nS
Range:
100 nS minimum; maximum defined by period and width (see note above)
Rounding: