Atec Rohde-Schwarz-FSH Series User Manual
Page 18
Version 15.01, July 2013
18
Rohde & Schwarz R&S
®
FSH4/R&S
®
FSH8/R&S
®
FSH13/ R&S
®
FSH20 Spectrum Analyzer
Frequency range
15 MHz to 3.0 GHz
Carrier frequency uncertainty
test case 6.3 in line with 3GPP TS 25.142
Lock range
±5 kHz
Measurement uncertainty
SNR > 30 dB,
∆f
ref
= uncertainty of reference frequency
< 10 Hz + ∆f
ref
RF channel power
test case 6.2 in line with 3GPP TS 25.142, SNR > 30 dB
Measurement range
frequency > 15 MHz
preamplifier = off
–60 dBm < P
RF channel
< 20 dBm
preamplifier = on
–75 dBm < P
RF channel
< 20 dBm
Measurement uncertainty
–75 dBm < P
RF channel
< 20 dBm,
P
REF_LEV
– 30 dB < P
RF channel
< P
REF_LEV
+
3 dB
< 1 dB, typ. 0.5 dB
P-CCPCH Symbol EVM
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
single channel EVM
1.5 % < EVM < 25 %
Measurement uncertainty
1.5 % < EVM ≤ 10 %
typ. 0.5 %
10 % < EVM < 25 %
typ. 2.5 %
Residual EVM
typ. 0.8 %
Data power, data 1/2 power, midamble
power
SNR > 30 dB
Measurement range
–60 dBm < P
data, midamble
< 20 dBm
Measurement uncertainty
–40 dBm < P
data, midamble
< 20 dBm
< 1 dB, typ. 0.5 dB
Composite EVM
test case 6.8.1 in line with 3GPP TS 25.142, SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
1.5 % < EVM < 25 %
Measurement uncertainty
1.5 % < EVM ≤ 10 %
typ. 1.0 %
10 % < EVM < 25 %
typ. 2.5 %
Residual EVM
typ. 1.0 %
Code domain power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
code
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
Code
< P
RF channel
< 1 dB, typ. 0.5 dB
Sync ID detection
Lock range
±5 kHz