The specifications below apply to the R&S
®
FSH4 and R&S
®
FSH8. They are based on the data sheet specifications of the R&S
®
FSH4
and R&S
®
FSH8, have not been checked separately and are not verified during instrument calibration. Measurement uncertainties are
indicated as 95 % confidence intervals. The specified level measurement errors do not take into account systematic errors due to
reduced signal-to-noise ratio (SNR).
Measurements R&S
®
FSH-K47 R&S
®
FSH-K47E
Spectrum overview
●
●
Result summary
●
●
RF channel power
●
●
Pilot Rho
●
●
Carrier frequency error
●
●
Traffic activity
●
●
Pilot EVM
●
●
PN timing (tau)
●
●
Peak to average
●
●
Pilot power
●
●
MAC power
●
●
Data power
●
●
PN scanner
–
●
Detected PN offset
–
●
Power per detected PN offset
–
●
Burst power
–
●
RF channel power
–
●
Pilot power
–
●
All specifications are valid for RC3, one traffic channel, SNR > 30 dB.
Frequency range
15 MHz to 3.0 GHz
Carrier frequency uncertainty, nominal values
Lock range
±5 kHz
Measurement uncertainty
SNR > 30 dB,
∆f
ref
= uncertainty of reference frequency
< 100 Hz + ∆f
ref
RF channel power
Measurement range
frequency > 15 MHz
preamplifier = off
–60 dBm < P
RF channel
< 20 dBm
preamplifier = on
–75 dBm < P
RF channel
< 20 dBm
Measurement uncertainty
–75 dBm < P
RF channel
< 20 dBm,
ref. level adjusted to RF channel power
< 1 dB, typ. 0.5 dB
Pilot power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
PICH
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
CPICH
< P
RF channel
< 1 dB, typ. 0.5 dB
MAC power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
SYNC
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
SYNC
< P
RF channel
< 1 dB, typ. 0.5 dB
Data power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
SYNC
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
SYNC
< P
RF channel
< 1 dB, typ. 0.5 dB
Pilot EVM
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
1.5 % < EVM < 25 %
Measurement uncertainty
1.5 % < EVM ≤ 10 %
typ. 2.0 %
10 % < EVM < 25 %
typ. 2.5 %
Residual EVM
typ. 2.5 %
Pilot Rho
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
0.9 < Rho < 1
Measurement uncertainty
0.97 < Rho ≤ 1.0
typ. 0.005
0.90 < Rho ≤ 0.97
typ. 0.02