Atec Rohde-Schwarz-FSH Series User Manual
Page 15
Version 15.01, July 2013
Rohde & Schwarz R&S
®
FSH4/R&S
®
FSH8/R&S
®
FSH13/ R&S
®
FSH20 Spectrum Analyzer 15
Frequency range
15 MHz to 3.0 GHz
Carrier frequency uncertainty, nominal values
Lock range
±10 kHz
Measurement uncertainty
SNR > 30 dB,
∆f
ref
= uncertainty of reference frequency
< 10 Hz + ∆f
ref
RF channel power
Measurement range
frequency > 15 MHz
preamplifier = off
–60 dBm < P
RF channel
< 20 dBm
preamplifier = on
–75 dBm < P
RF channel
< 20 dBm
Measurement uncertainty
–75 dBm < P
RF channel
< 20 dBm,
ref. level adjusted to RF channel power
< 1 dB, typ. 0.5 dB
PICH power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
PICH
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
CPICH
< P
RF channel
< 1 dB, typ. 0.5 dB
F-SYNC power
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
P
RF channel
– 20 dB < P
SYNC
< P
RF channel
Measurement uncertainty
P
RF channel
– 20 dBm < P
SYNC
< P
RF channel
< 1 dB, typ. 0.5 dB
Composite EVM
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
1.5 % < EVM < 25 %
Measurement uncertainty
1.5 % < EVM ≤ 10%
typ. 2.0 %
10 % < EVM < 25 %
typ. 2.5 %
Residual EVM
typ. 2.5 %
Rho
SNR > 30 dB
Measurement range
–40 dBm < P
RF channel
< 20 dBm
0.9 < Rho < 1
Measurement uncertainty
0.97 < Rho ≤ 1.0
typ. 0.005
0.90 < Rho ≤ 0.97
typ. 0.02