beautypg.com

Other options, Ber measurement (r&s, Smj-k80 option) – Atec Rohde-Schwarz-SMJ100A User Manual

Page 31: Bler measurement (r&s

background image

Version 05.00, December 2007

R&S

®

SMJ100A Vector Signal Generator

31

Other options

BER measurement (R&S

®

SMJ-K80 option)

The data supplied by the DUT is compared with a reference pseudo-random bit sequence.

Clock

supplied by DUT; a clock pulse is required
for each valid bit

Clock rate

100 Hz to 60 MHz

PRBS

sequence length

9, 11, 15, 16, 20, 21, 23

pattern ignore

OFF, all 0, all 1

data enable

external

modes

OFF, high, low

restart external

Data

modes ON/OFF

Synchronization time

28 clock cycles

Interface

9-pin D-Sub connector, D-Sub/BNC cable supplied with option
input impedance

1 k

Ω, 50 Ω

trigger threshold

setting range

0 V to 2.50 V

Clock, data, enable, and restart inputs

resolution 0.01

V

Polarity

data, clock, data enable

normal, inverted

Measurement time

selectable by means of maximum number
of data bits or bit errors (max. 2

31

bit

each), continuous measurement

Measurement result

if selected number of data bits or bit errors
is attained

BER in ppm, %, or decade values

Status displays

not synchronized, no clock, no data

BLER measurement (R&S

®

SMJ-K80 option)

In BLER measurement mode, arbitrary data can be provided by the DUT. A signal marking the block’s CRC has to be provided on the
data enable connector of the BER/BLER option.

Clock

supplied by DUT; a clock pulse is required
for each valid bit

Clock rate

100 Hz to 60 MHz

input data

arbitrary

data enable (marking the block’s CRC)

external

Data

modes high,

low

CRC type

CCITT CRC16 (x

16

+ x

12

+ x

5

+ 1)

CRC

CRC bit order

MSB first, LSB first

Synchronization time

1 block

Interface

9-pin D-Sub connector, D-Sub/BNC cable supplied with option
input impedance

1 k

Ω, 50 Ω

trigger threshold

setting range

0 V to 2.50 V

Clock, data, and enable inputs

resolution 0.01

V

Polarity

data, clock, data enable

normal, inverted

Measurement time

selectable by means of maximum number of received blocks or errors (max. 2

31

blocks

each), continuous measurement

Measurement result

if selected number of received blocks or
errors is attained

BLER in ppm, %, or decade values

Status displays

not synchronized, no clock, no data