Analog modulation, Internal modulation generator, Input for external modulation signals – Atec Rohde-Schwarz-SMJ100A User Manual
Page 11: Amplitude modulation
Version 05.00, December 2007
R&S
®
SMJ100A Vector Signal Generator
11
Analog modulation
Internal modulation generator
Frequency range
0.1 Hz to 1 MHz
Resolution of setting
0.1 Hz
Frequency uncertainty
<0.012 Hz +
relative deviation of reference frequency
up to 100 kHz
<0.1 dB
Frequency response
up to 1 MHz
<1 dB
Distortion
up to 100 kHz at R
L
>200
Ω, level (V
p
) 1 V <0.1 %
V
p
at LF connector, R
L
>200
Ω
1 mV to 3 V
resolution 1
mV
Output voltage
setting uncertainty at 1 kHz
<(1 % of reading + 1 mV)
Output impedance
16
Ω
Frequency setting time
to within <1 × 10
−7
, with GUI update
stopped, after IEC/IEEE bus delimiter
<3 ms
digital sweep in discrete steps
operating modes
automatic, step, single,
external single, external step,
manual or external trigger,
linear or logarithmic spacing
sweep range
full frequency range
linear step width
full frequency range
Sweep
logarithmic step width
0.01 % to 100 % per step
Input for external modulation signals
input impedance
high (>100 k
Ω), switchable to 50 Ω
with R&S
®
SMJ-B20 option
input sensitivity (peak value for set
modulation depth or deviation)
1 V
Modulation input
EXT MOD
absolute maximum rating
10 V
Amplitude modulation
Operating modes
internal, external AC/DC
Modulation depth
At high levels, modulation is clipped if the
maximum PEP is reached.
0 % to 100 %
Resolution
0.1
%
Setting uncertainty
attenuator mode Auto,
f
mod
= 1 kHz and m <80 %
<(1 % of reading + 1 %)
PEP in specified range, attenuator mode
Auto
f
≤ 3 GHz, at f
mod
= 1 kHz
m = 30 %
<0.5 %
m = 80 %
<0.8 %
f > 3 GHz, at f
mod
= 1 kHz
m = 30 %
<1 %
AM distortion
m = 80 %
<1.6 %
Modulation frequency range
DC, 20 Hz to 500 kHz
Modulation frequency response
AC mode, 20 Hz to 500 kHz
<1 dB
Incidental φM at AM
m = 30 %, f
mod
= 1 kHz, peak value
<0.1 rad