beautypg.com

Imagine your counter doing more, Introduction, Measurement by model – Atec Agilent-53200A Series User Manual

Page 2

background image

2

Introduction

Frequency counters are depended on in R&D and in manufacturing for the fastest, most accurate frequency and time
interval measurements. The 53200 Series of RF and universal frequency counter/timers expands on this expectation to
provide you with the most information, connectivity and new measurement capabilities, while building on the speed and
accuracy you’ve depended on with Agilent’s decades of time and frequency measurement expertise.

Three available models offer resolution capabilities up to 12 digits/sec frequency resolution on a one second gate. Single-
shot time interval measurements can be resolved down to 20 psec. All models offer new built-in analysis and graphing
capabilities to maximize the insight and information you receive.

More Bandwidth
• 350 MHz baseband frequency
• 6 or 15 GHz optional microwave
channels
More Resolution & Speed
• 12 digits/sec
• 20 ps single-shot time resolution
• Up to 75,000 and 90,000 readings/
sec (frequency and time interval)
More Insight
• Datalog trend plot
• Cumulative histogram
• Built-in math analysis and statistics
• 1M reading memory and USB Flash
storage

More Connectivity
• LXI-C/Ethernet LAN, USB, GPIB
• Optional battery for unstable AC
power or timebase accuracy

More Measurement Capability
(53230A only)
• Continuous gap-free measurements
• Basic measurement and
timestamps for modulation domain
analysis

(MDA)

• Optional pulse/burst microwave

measurement

Imagine Your Counter Doing More!

Measurements

Model

Standard

350 MHz Input

Channel(s)

Opt MW Inputs

(53210A: Ch 2,

53220A/30A: Ch 3)

Frequency

53210A,
53220A,

53230A

Frequency ratio

53210A,
53220A,

53230A

Period

53210A,
53220A,

53230A

Minimum/maximum/
peak-to-peak input
voltage

53210A,
53220A,

53230A

RF signal strength

53210A,
53220A,

53230A

Single period

53220A,

53230A

Time interval A to B, B
to A, A, B

53220A,

53230A

Positive/negative
pulse width

53220A,

53230A

Rise/fall time

53220A,

53230A

Positive/negative duty

53220A,

53230A

Phase A to B,
B to A

53220A,

53230A

Totalize
(continuous or timed)

53220A,

53230A

Continuous/gap-free

53230A

Timestamp 53230A

Pulse/burst measure-
ment software

1

53230A

(Option 150)

Measurement by model

1. Burst carrier frequency, pulse repetition frequency (PRF), pulse repetition interval (PRI),
burst positive width (“on” time), burst negative width (“off” time).