Third-order intermodulation distortion (TOI)
Parentheses indicate typical performance
RF (Option 503, 507)
Preamp off
(Two –20 dBm tones at input mixer spaced by
100 kHz, 0 dB attenuation, 20 to 30 °C)
10 to 400 MHz
+10 (+14) dBm
400 MHz to 3 GHz
+13 (+17) dBm
3 to 7.5 GHz
+13 (+15) dBm
MW (Option 513/526)
Preamp off
(Two –20 dBm tones at input mixer spaced by
100 kHz, 0 dB attenuation, 20 to 30 °C)
10 to 500 MHz
+11 dBm, (+15) dBm
500 MHz to 2 GHz
+12 dBm, (+15) dBm
2 to 3 GHz
+11 dBm, (+15) dBm
3 to 7.5 GHz
+12 dBm, (+17) dBm
7.5 to 13.6 GHz
+11 dBm, (+15) dBm
13.6 to 26.5 GHz
+10 dBm, (+14) dBm
Option P03/P07/P13/
P26
Preamp on
(Two –45 dBm tones at the preamp input, spaced by
100 kHz, 0 dB attenuation, 20 to 30 °C)
10 MHz to 26.5 GHz
–8 dBm nominal
Nominal dynamic range at 1 GHz for RF CXA
-130
-120
-110
-100
-90
-80
-70
-60
-80 -70 -60 -50 -40 -30 -20
Mixer level (dBm)
DANL
(1 Hz RBW)
2nd harmonic
distortion
3rd order
intermodulation
DANL and distortion
relative to mixer level (dB)
Nominal dynamic range bands 1-6 for RF CXA
-130
-120
-110
-100
-90
-80
-70
-60
-80 -70 -60 -50 -40 -30 -20
Mixer level (dBm)
DANL at 5.2 GHz
(1 Hz RBW)
2nd harmonic
distortion
at 3.75 GHz
3rd order
intermodulation
at 5.2 GHz
DANL and distortion
relative to mixer level (dB)
Figure 1. Nominal dynamic range for
Options 503 and 507 – Band 0, for second
and third order distortion, 10 MHz to
3 GHz
Figure 2. Nominal dynamic range for
Options 503 and 507 – Bands 1 to 6, for
second and third order distortion, 3 GHz
to 7.5 GHz
Nominal dynamic range for Options 503 and 507