Narrow pulse modulation – Atec Agilent-N5183A User Manual
Page 13
13
Narrow pulse modulation
1
(Option UNW)
500 MHz to 3.2 GHz
Above 3.2 GHz
On/Off ratio
> 80 dB (typ)
> 80 dB (typ)
Rise/Fall times (Tr, Tf)
< 10 ns (7 ns)
< 10 ns (7 ns)
Minimum pulse width
Internally leveled
≥ 2 us
≥ 2 us
ALC
off
2
≥ 20 ns
≥ 20 ns
Repetition frequency
Internally leveled
10 Hz to 500 kHz
10 Hz to 500 kHz
ALC
off
2
DC to 5 MHz
DC to 10 MHz
Level accuracy relative to CW
Internally leveled
< ±1.0 dB (typ)
< ±1.0 dB (typ)
ALC
off
2
±1.0 dB (typ)
±1.0 dB (typ)
Width compression
< 5 ns (typ)
< 10 ns (typ)
RF width relative to video out
Video feed-through
3
< 300 mV (typ)
< 10 mV (typ)
Video delay -
30 ns (nom)
30 ns (nom)
ext input to video
RF delay -video to
10 ns (nom)
20 ns (nom)
RF output
Pulse overshoot
< 15% (nom)
< 15% (nom)
Input level
+1 Vpeak = RF On
+1 Vpeak = RF On
Input impedance
50 Ω (nom)
50 Ω (nom)
1.
Pulse specifications apply to frequencies > 500 MHz. Operable down to 10 MHz.
2. With power search on.
3. Applies to power levels < +10 dBm.
Sync
Output
Video
Output
RF Pulse
Output
Td
Tm
Tw
Trf
Vf
Tf
Tr
Vor
Tp
50%
50%
10%
90%
50%
Td Video delay (variable)
Tw Video pulse width
(variable)
Tp Pulse period (variable)
Tm RF delay
Trf RF pulse width
Tf RF pulse fall time
Tr RF pulse rise time
Vor Pulse overshoot
Vf Video feedthrough