Analog modulation, Frequency modulation, Frequency bands – Atec Agilent-N5183A User Manual
Page 10
10
Frequency modulation
(Option UNT)
Maximum deviation
N x 10 MHz (nom)
Resolution
0.1% of deviation or 1 Hz, whichever is
greater
(nom)
Deviation accuracy
< ± 2% + 20 Hz
1 kHz rate, deviation is N x 50 kHz
Modulation frequency response (
at 100 kHz deviation)
1 dB bandwidth
3 dB bandwidth
DC coupled
DC to 3 MHz (nom)
DC to 7 MHz (nom)
AC coupled
5 Hz to 3 MHz (nom)
5 Hz to 7 MHz (nom)
Carrier frequency accuracy
< ±0.2% of set deviation + (N x 1 Hz)
2
relative to CW in DCFM
< ±0.06% of set deviation + (N x 1 Hz) (typ)
3
Distortion
< 0.4%
1 kHz rate, deviation is N x 50 kHz
Sensitivity when using
external input
+1V peak for indicated deviation (nom)
Analog Modulation
Frequency bands
1
Frequency
N
100 kHz to < 250 MHz
1
250 to < 375 MHz
0.250
375 to < 750 MHz
0.500
750 to < 1.5 GHz
1
1.5 to < 3.0 GHZ
2
3.0 to < 6.0 GHz
4
6.0 to < 12.0 GHz
8
12.0 to < 24.0 GHz
16
24.0 to 40 GHz
32
1.
N is a factor used to help define frequency and phase modulation specifications within the document.
2.
Specification valid for temperature changes of less than ± 5° C since last DCFM calibration.
3. Typical performance immediately after a DCFM calibration.